Schneider Electric

Schneider Electric LC1D50G7 IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D50G7
MPN:
LC1D50G7
Condition:
New
Warranty:
18 months
Eu Rohs Directive:
Compliant
Environmental Disclosure:
ENVPEP110205EN
Operating Time:
12...26 ms closing || 4...19 ms opening
Pvc Free:
Yes
Reach Free Of Svhc:
Yes
Motor Power Kw:
22 kW at 380...400 V AC 50/60 Hz (AC-3) || 25 kW at 415 V AC 50/60 Hz (AC-3) || 30 kW at 440 V AC 50/60 Hz (AC-3) || 30 kW at 500 V AC 50/60 Hz (AC-3) || 33 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 220...230 V AC 50/60 Hz (AC-3) || 11 kW at 4
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA || 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL || 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA || 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Insulation Resistance:
> 10 MOhm for control circuit
Overvoltage Category:
III
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Connections - Terminals:
control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-2.5 mm² - cable s
Auxiliary Contact Composition:
1 NO + 1 NC
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Flame Retardance:
V1 conforming to UL 94
Minimum Switching Voltage:
17 V for control circuit
Mechanical Durability:
6000000 cycles
Sustainable Offer Status:
Green Premium product
Poles Description:
3P
Standards:
UL 508 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-5-1 || CSA C22.2 No 14 || IEC 60947-4-1
Tightening Torque:
control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw clamp terminal flat Ø 6 mm || power circuit 5 N.m screw clamp terminal flat Ø 8 mm || control circui
Auxiliary Contacts Type:
mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
Ip Degree Of Protection:
IP2X IEC 60529 || IP2X VDE 0106
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Power Dissipation Per Pole:
3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
Contactor Application:
motor control || resistive load
Control Circuit Type:
AC 50/60 Hz
Range:
TeSys
Protective Cover:
with
Height:
122 mm
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Mercury Free:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat
Net Weight:
1.4 kg
Weight:
1.4 kg
Control Circuit Voltage Limits:
0.3...0.6 Uc 60-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc 60-60°C operational AC 50 Hz || 0.85...1.1 Uc 60-60°C operational AC 60 Hz
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pole Contact Composition:
3 NO
Irms Rated Making Capacity:
140 A AC for control circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
Inrush Power In Va:
140-140 VA cos phi 0.75 (at 20°C) || 160-160 VA cos phi 0.75 (at 20°C)
Product Or Component Type:
contactor
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 80 A (at 60°C) for power circuit
Operating Altitude:
9842.52 ft (3000 m) without derating
$388.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose