Schneider Electric

Schneider Electric LC1D50M7 IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D50M7
MPN:
LC1D50M7
Condition:
New
Operating Time:
4...19 ms opening || 12...26 ms closing
Standards:
UL 508 || IEC 60947-5-1 || EN 60947-4-1 || IEC 60947-4-1 || EN 60947-5-1 || CSA C22.2 No 14
Mercury Free:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Minimum Switching Current:
5 mA for control circuit
Mounting Support:
rail || plate
Power Dissipation Per Pole:
3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Range Of Product:
TeSys Deca
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Irms Rated Making Capacity:
900 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for control circuit conforming to IEC 60947-5-1
Pvc Free:
Yes
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Contactor Application:
motor control || resistive load
Country of Origin:
United States
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Rohs Exemption Information:
Yes
Device Short Name:
LC1D
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Mechanical Durability:
6000000 cycles
Product Or Component Type:
contactor
Tightening Torque:
control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2
Terminals Description Iso N°1:
(21-22)NC || (13-14)NO || (A1-A2)CO
Compatibility Code:
LC1D
Height:
127 mm
[Ie] Rated Operational Current:
50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Eu Rohs Directive:
Compliant
Auxiliary Contact Composition:
1 NO + 1 NC
Climatic Withstand:
IACS E10 exposure to damp heat
[Uc] Control Circuit Voltage:
220 V AC 50/60 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable en
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
Circularity Profile:
N/A
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Overvoltage Category:
III
Reach Free Of Svhc:
Yes
Fire Resistance:
850°C IEC 60695-2-1
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Weight:
1.4 kg
Insulation Resistance:
> 10 MOhm for control circuit
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Utilisation Category:
AC-4 || AC-3 || AC-1 || AC-2 || AC-3e
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 h
Pole Contact Composition:
3 NO
Minimum Switching Voltage:
17 V for control circuit
Sustainable Offer Status:
Green Premium product
$388.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose