Schneider Electric

Schneider Electric LC1D50T6 IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 480VAC 60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D50T6
MPN:
LC1D50T6
Condition:
New
Maximum Operating Rate:
3600 cyc/h 60°C
Environmental Disclosure:
ENVPEP110205EN
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Reach Free Of Svhc:
Yes
Toxic Heavy Metal Free:
Yes
Fire Resistance:
850°C IEC 60695-2-1
Mounting Support:
rail || plate
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Operating Time:
12...26 ms closing || 4...19 ms opening
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Minimum Switching Current:
5 mA for control circuit
Protective Cover:
with
Range Of Product:
TeSys Deca
Minimum Switching Voltage:
17 V for control circuit
Ip Degree Of Protection:
IP2X IEC 60529 || IP2X VDE 0106
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Hold-In Power Consumption In Va:
13-13 VA 50 Hz cos phi 0.3 (at 20°C) || 15-15 VA 60 Hz cos phi 0.3 (at 20°C)
Motor Power Kw:
22 kW at 380...400 V AC 50/60 Hz || 25 kW at 415 V AC 50/60 Hz || 30 kW at 440 V AC 50/60 Hz || 30 kW at 500 V AC 50/60 Hz || 33 kW at 660...690 V AC 50/60 Hz || 15 kW at 220...230 V AC 50/60 Hz
Tightening Torque:
control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw clamp terminal flat Ø 6 mm || power circuit 5 N.m screw clamp terminal flat Ø 8 mm || control circui
Auxiliary Contacts Type:
mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Control Circuit Type:
AC 60 Hz
Eu Rohs Directive:
Compliant
Rohs Exemption Information:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Contactor Application:
motor control || resistive load
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Connections - Terminals:
control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-2.5 mm² - cable s
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Utilisation Category:
AC-1 || AC-2 || AC-4 || AC-3 || AC-3e
Poles Description:
3P
Country of Origin:
Czechia
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Range:
TeSys
Pvc Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Overvoltage Category:
III
Depth:
119 mm
Permissible Ambient Air Temperature Around The Device:
-5-60°C || -40-70°C at Uc
Operating Altitude:
9842.52 ft (3000 m) without derating
Product Certifications:
RINA || CCC || CSA || GL || GOST || BV || DNV || UL || LROS (pending) || UKCA
Insulation Resistance:
> 10 MOhm for control circuit
Product Or Component Type:
contactor
$388.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 480 VAC60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose