Schneider Electric LC1D65008M7 IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 2 NO and 2 NC, 220VAC 50/60Hz coil, open style
Schneider Electric
$748.80
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 220 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 4.92 inches deep. It weighs 3.20 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Environmental Disclosure:
- ENVPEP110205EN
- Power Dissipation Per Pole:
- 9.6 W AC-1
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Range:
- TeSys
- Product Or Component Type:
- contactor
- Mechanical Robustness:
- shocks contactor open 8 Gn for 11 ms) || shocks contactor closed 10 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 3 Gn, 5...300 Hz)
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Associated Fuse Rating:
- 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
- Rohs Exemption Information:
- Yes
- Weight:
- 1.45 kg
- Utilisation Category:
- AC-1
- Toxic Heavy Metal Free:
- Yes
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Coil Technology:
- without built-in suppressor module
- Contactor Application:
- resistive load
- Eu Rohs Directive:
- Compliant
- Protective Treatment:
- THIEC 60068-2-30
- Poles Description:
- 4P
- Circularity Profile:
- N/A
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Reach Free Of Svhc:
- Yes
- Warranty:
- 18 months
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Depth:
- 125 mm
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
- Overvoltage Category:
- III
- Width:
- 85 mm
- Control Circuit Type:
- AC 50/60 Hz
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- [Uc] Control Circuit Voltage:
- 220 V AC 50/60 Hz
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Device Short Name:
- LC1D
- Product Certifications:
- RINA || BV || CSA || UL || LROS (Lloyds register of shipping) || CCC || DNV || GL || GOST
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Heat Dissipation:
- 4-5 W at 50/60 Hz
- Climatic Withstand:
- IACS E10 exposure to damp heat
- Pvc Free:
- Yes
- Protective Cover:
- without
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Net Weight:
- 1.45 kg
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Mercury Free:
- Yes
- [Ith] Conventional Free Air Thermal Current:
- 80 A (at 60°C) for power circuit
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- [Icw] Rated Short-Time Withstand Current:
- 640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit