Schneider Electric LC1D65A6EHE IEC contactor, TeSys Deca Green, nonreversing, 65A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 130VAC/VDC coil, open style
Schneider Electric
$403.00
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.21 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Device Short Name:
- LC1D
- Pollution Degree:
- 3
- [Ith] Conventional Free Air Thermal Current:
- 80 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Poles Description:
- 3P
- Sustainable Offer Status:
- Green Premium product
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Mechanical Durability:
- 6 Mcycles
- Mounting Support:
- rail || plate
- Operating Time:
- 55...65 ms closing || 20...80 ms opening
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Rohs Exemption Information:
- Yes
- Product Or Component Type:
- contactor
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Width:
- 55 mm
- Control Circuit Voltage Limits:
- <= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
- Signaling Circuit Frequency:
- 25...400 Hz
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Mercury Free:
- Yes
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947
- Weight:
- 1.002 kg
- Associated Fuse Rating:
- 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
- Circularity Profile:
- ENVEOLI1607010EN
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC-3e for power circuit
- Contactor Application:
- motor control || resistive load
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Inrush Power In W:
- 19-19 W 20°C)
- Inrush Power In Va:
- 23-23 VA 50/60 Hz (at 20°C)
- Pole Contact Composition:
- 3 NO
- Net Weight:
- 1.002 kg
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Flame Retardance:
- V1 conforming to UL 94
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Country of Origin:
- France
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Warranty:
- 18 months
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Hold-In Power Consumption In Va:
- 1.4-1.4 VA 50/60 Hz (at 20°C)
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Maximum Horse Power Rating:
- 5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp