Schneider Electric

Schneider Electric LC1D65A6R7 IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 440VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D65A6R7
MPN:
LC1D65A6R7
Condition:
New
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Minimum Switching Current:
5 mA for Signaling circuit
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Contactor Application:
motor control || resistive load
Reach Free Of Svhc:
Yes
Protective Treatment:
THIEC 60068-2-30
Sustainable Offer Status:
Green Premium product
Fire Resistance:
850°C IEC 60695-2-1
Heat Dissipation:
4-5 W at 50/60 Hz
Pole Contact Composition:
3 NO
Maximum Horse Power Rating:
40 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 5 hp at 115 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 20 hp at 230/240 V AC 50/60 Hz for 3 phase
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
[Uc] Control Circuit Voltage:
440 V AC 50/60 Hz
Net Weight:
0.86 kg
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Rohs Exemption Information:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Minimum Switching Voltage:
17 V for Signaling circuit
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Pollution Degree:
3
Product Or Component Type:
contactor
Environmental Disclosure:
ENVPEP1503009EN
Protective Cover:
with
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Insulation Resistance:
> 10 MOhm for Signaling circuit
Range Of Product:
TeSys Deca
Range:
TeSys || TeSys Deca
Pvc Free:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Flame Retardance:
V1 conforming to UL 94
Mercury Free:
Yes
Mechanical Durability:
6 Mcycles
Toxic Heavy Metal Free:
Yes
Mounting Support:
rail || plate
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Power Dissipation Per Pole:
9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
Tightening Torque:
control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm M3.5 || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 M3.5 || power circuit 6 N.m EverLink BTR screw connectors hexagonal 10 mm M6 || control circuit 1.7 N.m Ever
$386.40

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. Contactor is supplied with a 440 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose