Schneider Electric LC1D65A6U7 IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 240VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D65A6U7
MPN:
LC1D65A6U7
Condition:
New
Environmental Disclosure:
ENVPEP1503009EN
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Mechanical Durability:
6 Mcycles
Weight:
0.86 kg
Device Short Name:
LC1D
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Maximum Horse Power Rating:
40 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 5 hp at 115 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 20 hp at 230/240 V AC 50/60 Hz for 3 phase
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Minimum Switching Current:
5 mA for Signaling circuit
Motor Power Kw:
11 kW at 400 V AC 50/60 Hz (AC-4) || 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) || 30 kW at 380...400 V AC 50/60 Hz (AC-3) || 37 kW at 500 V AC 50/60 Hz (AC-3) || 37 kW at 660...690 V AC 50/60 Hz (AC-3) || 18.5 kW at 220...230 V AC 50/60 Hz (AC-3e) ||
Mounting Support:
plate || rail
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Operating Altitude:
0...9842.52 ft (0...3000 m)
Heat Dissipation:
4-5 W at 50/60 Hz
Reach Free Of Svhc:
Yes
Toxic Heavy Metal Free:
Yes
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Poles Description:
3P
Tightening Torque:
control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm M3.5 || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 M3.5 || power circuit 6 N.m EverLink BTR screw connectors hexagonal 10 mm M6 || control circuit 1.7 N.m Ever
Mercury Free:
Yes
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Range Of Product:
TeSys Deca
Circularity Profile:
ENVEOLI1503009EN
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
[Uc] Control Circuit Voltage:
240 V AC 50/60 Hz
Power Dissipation Per Pole:
9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Height:
122 mm
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Coil Technology:
without built-in suppressor module
Pvc Free:
Yes
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
Auxiliary Contact Composition:
1 NO + 1 NC
Rohs Exemption Information:
Yes
Operating Time:
4...19 ms opening || 12...26 ms closing
Minimum Switching Voltage:
17 V for Signaling circuit
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Maximum Operating Rate:
3600 cyc/h 60°C
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Pollution Degree:
3
Warranty:
18 months
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 16.5 mm
Net Weight:
0.86 kg
$386.40

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.