Schneider Electric

Schneider Electric LC1D65ABD IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D65ABD
MPN:
LC1D65ABD
Condition:
New
Minimum Switching Current:
5 mA for Signaling circuit
Rohs Exemption Information:
Yes
Operating Time:
50±15 % ms closing || 16...24 ms opening
Tightening Torque:
control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BT
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Mechanical Durability:
10 Mcycles
Poles Description:
3P
Mounting Support:
plate || rail
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Circularity Profile:
ENVEOLI1503009EN
Protective Cover:
with
Flame Retardance:
V1 conforming to UL 94
Width:
55 mm
Maximum Operating Rate:
3600 cyc/h 60°C
Sustainable Offer Status:
Green Premium product
Weight:
0.935 kg
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Fire Resistance:
850°C IEC 60695-2-1
Pvc Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Pollution Degree:
3
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Time Constant:
34 ms
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Inrush Power In W:
19-19 W 20°C)
Sustainable Packaging:
Yes
Product Or Component Type:
contactor
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Maximum Horse Power Rating:
40 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 5 hp at 115 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 20 hp at 230/240 V AC 50/60 Hz for 3 phase
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Signaling Circuit Frequency:
25...400 Hz
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Net Weight:
0.935 kg
Motor Power Kw:
11 kW at 400 V AC 50/60 Hz (AC-4) || 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) || 30 kW at 380...400 V AC 50/60 Hz (AC-3) || 37 kW at 500 V AC 50/60 Hz (AC-3) || 37 kW at 660...690 V AC 50/60 Hz (AC-3) || 18.5 kW at 220...230 V AC 50/60 Hz (AC-3e) ||
Mercury Free:
Yes
[Uc] Control Circuit Voltage:
24 V DC
Range:
TeSys || TeSys Deca
Depth:
120 mm
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Overvoltage Category:
III
Reach Free Of Svhc:
Yes
Environmental Disclosure:
ENVPEP1503009EN
Device Short Name:
LC1D
$403.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose