- Product Certifications:
- CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
- Mercury Free:
- Yes
- Compatibility Code:
- LC1D
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Contactor Application:
- motor control || resistive load
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Sustainable Offer Status:
- Green Premium product
- Motor Power Kw:
- 11 kW at 400 V AC 50/60 Hz (AC-4) || 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) || 30 kW at 380...400 V AC 50/60 Hz (AC-3) || 37 kW at 500 V AC 50/60 Hz (AC-3) || 37 kW at 660...690 V AC 50/60 Hz (AC-3)
- Device Short Name:
- LC1D
- Reach Free Of Svhc:
- Yes
- Environmental Disclosure:
- ENVPEP1503009EN
- Range Of Product:
- TeSys Deca
- Control Circuit Type:
- DC standard
- Utilisation Category:
- AC-4 || AC-1 || AC-3
- Pole Contact Composition:
- 3 NO
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
- Maximum Horse Power Rating:
- 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 5 hp at 115 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 20 hp at 230/240 V AC 50/60 Hz for 3 phase
- Flame Retardance:
- V1 conforming to UL 94
- Protective Cover:
- with
- Toxic Heavy Metal Free:
- Yes
- Control Circuit Voltage Limits:
- 0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Net Weight:
- 0.935 kg
- Electrical Durability:
- 0.5 Mcycles 80 A AC-1 <= 440 V || 1.45 Mcycles 65 A AC-3 <= 440 V
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Hold-In Power Consumption In W:
- 7.4-7.4 W 20°C
- Power Dissipation Per Pole:
- 9.6 W AC-1 || 6.3 W AC-3
- Mounting Support:
- rail || plate
- Rohs Exemption Information:
- Yes
- Weight:
- 0.935 kg
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Warranty:
- 18 months
- Depth:
- 120 mm
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Circularity Profile:
- ENVEOLI1503009EN
- Time Constant:
- 34 ms
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Eu Rohs Directive:
- Compliant
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Pollution Degree:
- 3
- Height:
- 122 mm