Schneider Electric

Schneider Electric LC1D65AEHE IEC contactor, TeSys Deca Green, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48/130VAC/VDC coil

(No reviews yet) Write a Review
SKU:
LC1D65AEHE
MPN:
LC1D65AEHE
Condition:
New
Minimum Switching Current:
5 mA for Signaling circuit
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Associated Fuse Rating:
125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC-3e for power circuit
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Rohs Exemption Information:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Operating Altitude:
0...9842.52 ft (0...3000 m)
Environmental Disclosure:
ENVPEP1607010EN
[Ith] Conventional Free Air Thermal Current:
80 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Net Weight:
1.002 kg
Auxiliary Contact Composition:
1 NO + 1 NC
Power Dissipation Per Pole:
9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
Compatibility Code:
LC1D
Inrush Power In W:
19-19 W 20°C)
Fire Resistance:
850°C IEC 60695-2-1
Motor Power Kw:
18.5 kW at 220...230 V AC 50 Hz (AC-3) || 30 kW at 380...400 V AC 50 Hz (AC-3) || 37 kW at 415 V AC 50 Hz (AC-3) || 37 kW at 440 V AC 50 Hz (AC-3) || 37 kW at 500 V AC 50 Hz (AC-3) || 37 kW at 660...690 V AC 50 Hz (AC-3) || 18.5 kW at 220...230 V AC
Operating Time:
55...65 ms closing || 20...120 ms opening >= 17221) || 20...80 ms opening >= 18011)
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Minimum Switching Voltage:
17 V for Signaling circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pole Contact Composition:
3 NO
Coil Technology:
built-in bidirectional peak limiting
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Protective Cover:
with
Halogen Content Performance:
Halogen free plastic parts & cables product
Range:
TeSys || TeSys Deca
Range Of Product:
TeSys Deca
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Width:
55 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Hold-In Power Consumption In Va:
1.4-1.4 VA 50/60 Hz (at 20°C)
Flame Retardance:
V1 conforming to UL 94
Mercury Free:
Yes
Signaling Circuit Frequency:
25...400 Hz
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Poles Description:
3P
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Hold-In Power Consumption In W:
0.9-0.9 W 20°C
Weight:
1.002 kg
Maximum Horse Power Rating:
5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp
Ip Degree Of Protection:
IP20 front face IEC 60529
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Depth:
120 mm
$162.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.21 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose