Schneider Electric LC1D65AK7 IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100VAC 50/60Hz coil, open
Schneider Electric
$386.40
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 100 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Sustainable Offer Status:
- Green Premium product
- Range:
- TeSys || TeSys Deca
- Pvc Free:
- Yes
- Contactor Application:
- motor control || resistive load
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Control Circuit Type:
- AC 50/60 Hz
- Net Weight:
- 0.86 kg
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Electrical Durability:
- 1.4 Mcycles 80 A AC-1 <= 440 V || 1.45 Mcycles 65 A AC-3 <= 440 V || 1.45 Mcycles 65 A AC-3e <= 440 V
- Toxic Heavy Metal Free:
- Yes
- Range Of Product:
- TeSys Deca
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Pollution Degree:
- 3
- Rohs Exemption Information:
- Yes
- Signaling Circuit Frequency:
- 25...400 Hz
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Utilisation Category:
- AC-4 || AC-1 || AC-3 || AC-3e
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Coil Technology:
- without built-in suppressor module
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
- Mercury Free:
- Yes
- Overvoltage Category:
- III
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947
- Mounting Support:
- plate || rail
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Protective Cover:
- with
- [Uc] Control Circuit Voltage:
- 100 V AC 50/60 Hz
- Country of Origin:
- Indonesia
- Eu Rohs Directive:
- Compliant
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Power Dissipation Per Pole:
- 9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Weight:
- 0.86 kg
- Product Or Component Type:
- contactor
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Protective Treatment:
- THIEC 60068-2-30
- Depth:
- 120 mm
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Environmental Disclosure:
- ENVPEP1503009EN
- Poles Description:
- 3P