Schneider Electric

Schneider Electric LC1D65F7 IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D65F7
MPN:
LC1D65F7
Condition:
New
Depth:
176 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Tightening Torque:
control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2 || control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm
Pvc Free:
Yes
Minimum Switching Current:
5 mA for control circuit
Hold-In Power Consumption In Va:
15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Circularity Profile:
N/A
Insulation Resistance:
> 10 MOhm for control circuit
Standards:
EN 60947-5-1 || UL 508 || CSA C22.2 No 14 || IEC 60947-5-1 || EN 60947-4-1
Range:
TeSys
Motor Power Kw:
11 kW at 400 V AC 50 Hz (AC-4) || 30 kW at 380...400 V AC 50 Hz (AC-3) || 37 kW at 500 V AC 50 Hz (AC-3) || 37 kW at 660...690 V AC 50 Hz (AC-3) || 18.5 kW at 220...230 V AC 50 Hz (AC-3) || 30 kW at 415 V AC 50 Hz (AC-3) || 37 kW at 1000 V AC 50 Hz (
Mechanical Robustness:
shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms)
[Ith] Conventional Free Air Thermal Current:
80 A (at 60°C) for power circuit || 10 A (at 60°C) for control circuit
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Utilisation Category:
AC-2 || AC-4 || AC-1 || AC-3e
Product Or Component Type:
contactor
Minimum Switching Voltage:
17 V for control circuit
Climatic Withstand:
IACS E10 exposure to damp heat
Poles Description:
3P
Safety Reliability Level:
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 || B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
Time Constant:
34 ms
Flame Retardance:
V1 conforming to UL 94
[Ie] Rated Operational Current:
65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Compatibility Code:
LC1D
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Associated Fuse Rating:
125 A gG at <= 690 V coordination type 2 for power circuit || 160 A gG at <= 690 V coordination type 1 for power circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 10 A gG for control circuit conformi
Warranty:
18 months
Power Dissipation Per Pole:
6.4 W AC-1 || 4.2 W AC-3e || 4.2 W AC-3
Irms Rated Making Capacity:
140 A AC for control circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947 || 250 A DC for control circuit conforming to IEC 60947-5-1
Net Weight:
2.185 kg
Ip Degree Of Protection:
IP2X VDE 0106 || IP2X IEC 60529
Maximum Operating Rate:
3600 cyc/h 60°C
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Toxic Heavy Metal Free:
Yes
Mechanical Durability:
10000000 cycles
Overvoltage Category:
III
[Uc] Control Circuit Voltage:
110 V DC
Operating Time:
12...26 ms closing || 50 ms closing || 20 ms opening
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Contactor Application:
resistive load || motor control
Control Circuit Voltage Limits:
0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz || 0.75...1.25 Uc -40-60°C operational DC || 0.1...0.3 Uc -40-70°C drop-out DC
Product Certifications:
CCC || GOST || CSA || RINA || LROS (Lloyds register of shipping) || BV || GL || UL || UKCA || DNV
Control Circuit Type:
DC standard
Inrush Power In W:
19-19 W 20°C)
Fire Resistance:
850°C IEC 60695-2-1
$532.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose