Schneider Electric

Schneider Electric LC1D65L6 IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 200VAC 60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D65L6
MPN:
LC1D65L6
Condition:
New
Auxiliary Contact Composition:
1 NO + 1 NC
Operating Time:
12...26 ms closing || 4...19 ms opening
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Height:
127 mm
Insulation Resistance:
> 10 MOhm for control circuit
[Uc] Control Circuit Voltage:
200 V AC 60 Hz
Climatic Withstand:
IACS E10 exposure to damp heat
Permissible Ambient Air Temperature Around The Device:
-5-60°C || -40-70°C at Uc
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability:
6000000 cycles
Protective Cover:
with
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Operating Altitude:
9842.52 ft (3000 m) without derating
Environmental Disclosure:
ENVPEP110205EN
Minimum Switching Voltage:
17 V for control circuit
Poles Description:
3P
Terminals Description Iso N°1:
(21-22)NC || (13-14)NO || (A1-A2)CO
Product Or Component Type:
contactor
Maximum Operating Rate:
3600 cyc/h 60°C
Maximum Horse Power Rating:
10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA || 10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL || 20 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA || 20 hp at 200/208 V AC 60 Hz for 3 phase motors
Contactor Application:
motor control || resistive load
Standards:
CSA C22.2 No 14 || IEC 60947-5-1 || EN 60947-4-1 || UL 508 || IEC 60947-4-1 || EN 60947-5-1
Ip Degree Of Protection:
IP2X IEC 60529 || IP2X VDE 0106
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mounting Support:
plate || rail
Net Weight:
1.4 kg
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Control Circuit Voltage Limits:
0.3...0.6 Uc 60-60°C drop-out AC 50/60 Hz || 0.85...1.1 Uc 60-60°C operational AC 60 Hz
Pole Contact Composition:
3 NO
Inrush Power In Va:
140-140 VA cos phi 0.75 (at 20°C) || 160-160 VA cos phi 0.75 (at 20°C)
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Compatibility Code:
LC1D
Power Dissipation Per Pole:
6.4 W AC-1
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Device Short Name:
LC1D
Flame Retardance:
V1 conforming to UL 94
Overvoltage Category:
III
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Toxic Heavy Metal Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Motor Power Kw:
30 kW at 440 V AC 50/60 Hz || 30 kW at 380...400 V AC 50/60 Hz || 37 kW at 500 V AC 50/60 Hz || 37 kW at 660...690 V AC 50/60 Hz || 18.5 kW at 220...230 V AC 50/60 Hz || 30 kW at 415 V AC 50/60 Hz || 37 kW at 1000 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Sustainable Offer Status:
Green Premium product
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 80 A (at 60°C) for power circuit
Rohs Exemption Information:
Yes
$532.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 200 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose