Schneider Electric

Schneider Electric LC1D80004G6 IEC contactor, TeSys Deca, nonreversing, 125A resistive, 4 pole, 4 NO, 120VAC 60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80004G6
MPN:
LC1D80004G6
Condition:
New
Protective Treatment:
THIEC 60068-2-30
Rohs Exemption Information:
Yes
Maximum Operating Rate:
3600 cyc/h 60°C
Mercury Free:
Yes
Height:
127 mm
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Motor Power Kw:
22 kW at 220...230 V AC 50/60 Hz || 37 kW at 380...400 V AC 50/60 Hz || 45 kW at 660...690 V AC 50/60 Hz || 55 kW at 500 V AC 50/60 Hz || 45 kW at 415...440 V AC 50/60 Hz
Mechanical Durability:
10 Mcycles
Depth:
125 mm
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Product Or Component Type:
contactor
Circularity Profile:
N/A
Ip Degree Of Protection:
IP20 front face IEC 60529
Mounting Support:
plate || rail
Coil Technology:
without built-in suppressor module
Electrical Durability:
0.8 Mcycles 125 A AC-1 <= 440 V
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Climatic Withstand:
IACS E10 exposure to damp heat
Fire Resistance:
850°C IEC 60695-2-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
Control Circuit Voltage Limits:
0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 60 Hz || 1...1.1 Uc 55-70°C operational AC 60 Hz
Flame Retardance:
V1 conforming to UL 94
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ue] Rated Operational Voltage:
power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Compatibility Code:
LC1D
Heat Dissipation:
6-10 W at 60 Hz
Net Weight:
1.76 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ie] Rated Operational Current:
125 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 55 A (at <60°C) at <= 400 V AC AC-4 for power circuit
Inrush Power In Va:
220-220 VA 60 Hz cos phi 0.75 (at 20°C)
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.
Reach Free Of Svhc:
Yes
Width:
96 mm
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Pvc Free:
Yes
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 990 A 40°C - 1 s for power circuit || 135 A 40°C - 10 min for power circuit || 320 A 40°C - 1 min for power circuit
[Uc] Control Circuit Voltage:
120 V AC 60 Hz
Range Of Product:
TeSys Deca
Weight:
1.76 kg
Pollution Degree:
3
Contactor Application:
resistive load
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Operating Time:
20...35 ms closing || 6...20 ms opening
Poles Description:
4P
$526.40

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 110A resistive load rating. Contactor is supplied with a 120 VAC 60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.78 inches wide and 4.92 inches deep. It weighs 3.88 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose