Schneider Electric

Schneider Electric LC1D806BD IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D806BD
MPN:
LC1D806BD
Condition:
New
Power Dissipation Per Pole:
5.1 W AC-3 || 12.5 W AC-1 || 5.1 W AC-3e
Circularity Profile:
N/A
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Inrush Power In W:
22-22 W 20°C)
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: bars 1 - busbar cross section: 3 x 16 mm || power circuit: lugs-ring terminals - external diameter: 17 mm
Pole Contact Composition:
3 NO
Utilisation Category:
AC-3 || AC-3e || AC-4 || AC-1
Minimum Switching Voltage:
17 V for Signaling circuit
Tightening Torque:
control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 5 N.m lugs-ring terminals flat Ø 8 mm M6 || power circuit 5 N.m lugs-ring terminals hexagonal 10 mm M6 ||
Fire Resistance:
850°C IEC 60695-2-1
Sustainable Offer Status:
Green Premium product
Maximum Operating Rate:
3600 cyc/h 60°C
Insulation Resistance:
> 10 MOhm for Signaling circuit
Rohs Exemption Information:
Yes
Protective Cover:
with
Coil Technology:
without built-in suppressor module
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Pvc Free:
Yes
Toxic Heavy Metal Free:
Yes
Environmental Disclosure:
ENVPEP110205EN
Weight:
2.59 kg
Hold-In Power Consumption In W:
22-22 W 20°C
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Sustainable Packaging:
Yes
Pollution Degree:
3
Operating Time:
95...130 ms closing || 20...35 ms opening
Flame Retardance:
V1 conforming to UL 94
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Electrical Durability:
0.8 Mcycles 125 A AC-1 <= 440 V || 1.5 Mcycles 80 A AC-3 <= 440 V || 1.5 Mcycles 80 A AC-3e <= 440 V
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Height:
127 mm
Overvoltage Category:
III
Operating Altitude:
0...9842.52 ft (0...3000 m)
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 990 A 40°C - 1 s for power circuit || 135 A 40°C - 10 min for power circuit || 320 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Country of Origin:
Czechia
[Ie] Rated Operational Current:
125 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Protective Treatment:
THIEC 60068-2-30
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
Depth:
186 mm
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Reach Free Of Svhc:
Yes
Contactor Application:
resistive load || motor control
Mechanical Durability:
10 Mcycles
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.85...1.1 Uc -40-55°C operational DC || 1...1.1 Uc 55-70°C operational DC
Motor Power Kw:
22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 k
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
$447.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 7.32 inches deep. It weighs 5.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose