Schneider Electric

Schneider Electric LC1D806F7 IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D806F7
MPN:
LC1D806F7
Condition:
New
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
Depth:
130 mm
Sustainable Offer Status:
Green Premium product
Utilisation Category:
AC-3 || AC-3e || AC-4 || AC-1
Product Or Component Type:
contactor
Mounting Support:
plate || rail
Hold-In Power Consumption In Va:
26-26 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C)
Control Circuit Voltage Limits:
0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
Auxiliary Contact Composition:
1 NO + 1 NC
Weight:
1.59 kg
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Compatibility Code:
LC1D
[Ue] Rated Operational Voltage:
power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
Maximum Operating Rate:
3600 cyc/h 60°C
Mechanical Durability:
4 Mcycles
Height:
127 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
Operating Altitude:
0...9842.52 ft (0...3000 m)
Circularity Profile:
N/A
Minimum Switching Voltage:
17 V for Signaling circuit
Overvoltage Category:
III
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Current:
5 mA for Signaling circuit
Climatic Withstand:
IACS E10 exposure to damp heat
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Protective Treatment:
THIEC 60068-2-30
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Insulation Resistance:
> 10 MOhm for Signaling circuit
Heat Dissipation:
6-10 W at 50/60 Hz
Protective Cover:
with
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Range Of Product:
TeSys Deca
Operating Time:
20...35 ms closing || 6...20 ms opening
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Fire Resistance:
850°C IEC 60695-2-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Type:
AC 50/60 Hz
Flame Retardance:
V1 conforming to UL 94
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Range:
TeSys
$363.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose