Schneider Electric

Schneider Electric LC1D806LE7 IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 208VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D806LE7
MPN:
LC1D806LE7
Condition:
New
Motor Power Kw:
22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 k
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Overvoltage Category:
III
Pollution Degree:
3
Product Or Component Type:
contactor
Mechanical Durability:
4 Mcycles
Eu Rohs Directive:
Compliant
Device Short Name:
LC1D
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
[Ie] Rated Operational Current:
125 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Compatibility Code:
LC1D
Climatic Withstand:
IACS E10 exposure to damp heat
Pole Contact Composition:
3 NO
Maximum Operating Rate:
3600 cyc/h 60°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Free Of Svhc:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Electrical Durability:
0.8 Mcycles 125 A AC-1 <= 440 V || 1.5 Mcycles 80 A AC-3 <= 440 V || 1.5 Mcycles 80 A AC-3e <= 440 V
Rohs Exemption Information:
Yes
Insulation Resistance:
> 10 MOhm for Signaling circuit
Tightening Torque:
control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 5 N.m lugs-ring terminals flat Ø 8 mm M6 || power circuit 5 N.m lugs-ring terminals hexagonal 10 mm M6 ||
Hold-In Power Consumption In Va:
26-26 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C)
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Utilisation Category:
AC-3 || AC-3e || AC-4 || AC-1
Protective Cover:
with
Depth:
130 mm
Toxic Heavy Metal Free:
Yes
Control Circuit Voltage Limits:
0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: bars 1 - busbar cross section: 3 x 16 mm || power circuit: lugs-ring terminals - external diameter: 17 mm
[Ue] Rated Operational Voltage:
power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
Warranty:
18 months
Circularity Profile:
N/A
Environmental Disclosure:
ENVPEP110205EN
Ip Degree Of Protection:
IP20 front face IEC 60529
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
Mercury Free:
Yes
Inrush Power In Va:
245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
Protective Treatment:
THIEC 60068-2-30
Operating Altitude:
0...9842.52 ft (0...3000 m)
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Pvc Free:
Yes
[Uc] Control Circuit Voltage:
208 V AC 50/60 Hz
$363.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 208 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose