TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Poles Description:
- 3P
- Pollution Degree:
- 3
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Depth:
- 120 mm
- Toxic Heavy Metal Free:
- Yes
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Product Or Component Type:
- contactor
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Rohs Exemption Information:
- Yes
- [Ue] Rated Operational Voltage:
- power circuit 690 V AC 25...400 Hz || power circuit 300 V DC
- Warranty:
- 18 months
- Weight:
- 0.86 kg
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Connections - Terminals:
- power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible with cable end || control circuit: spring terminals 1 0.75-2.5
- Overvoltage Category:
- III
- Flame Retardance:
- V1 conforming to UL 94
- Signaling Circuit Frequency:
- 25...400 Hz
- Coil Technology:
- without built-in suppressor module
- Compatibility Code:
- LC1D
- Mercury Free:
- Yes
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V AC for power circuit conforming to IEC 60947
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Mechanical Durability:
- 6 Mcycles
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Fire Resistance:
- 850°C IEC 60695-2-1
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Environmental Disclosure:
- ENVPEP1503009EN
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC-1 for power circuit || 66 A (at <60°C) at <= 440 V AC-3 for power circuit || 66 A (at <60°C) at <= 440 V AC-3e for power circuit
- [Uc] Control Circuit Voltage:
- 230 V AC 50/60 Hz
- [Ui] Rated Insulation Voltage:
- Signaling circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-4-1
- Electrical Durability:
- 0.7 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3 <= 440 V || 1 Mcycles 66 A AC-3e <= 440 V
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Net Weight:
- 0.86 kg
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Maximum Horse Power Rating:
- 5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp
- Protective Cover:
- with
- Range:
- TeSys || TeSys Deca
- Mounting Support:
- plate || rail
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- [Icw] Rated Short-Time Withstand Current:
- 520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Control Circuit Type:
- AC 50/60 Hz standard
- Height:
- 122 mm
- Pvc Free:
- Yes
- Eu Rohs Directive: