Schneider Electric

Schneider Electric LC1D80A3P7 IEC contactor, TeSys Deca, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 230VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80A3P7
MPN:
LC1D80A3P7
Condition:
New
Poles Description:
3P
Pollution Degree:
3
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Depth:
120 mm
Toxic Heavy Metal Free:
Yes
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Product Or Component Type:
contactor
Operating Altitude:
0...9842.52 ft (0...3000 m)
Rohs Exemption Information:
Yes
[Ue] Rated Operational Voltage:
power circuit 690 V AC 25...400 Hz || power circuit 300 V DC
Warranty:
18 months
Weight:
0.86 kg
Minimum Switching Voltage:
17 V for Signaling circuit
Connections - Terminals:
power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible with cable end || control circuit: spring terminals 1 0.75-2.5
Overvoltage Category:
III
Flame Retardance:
V1 conforming to UL 94
Signaling Circuit Frequency:
25...400 Hz
Coil Technology:
without built-in suppressor module
Compatibility Code:
LC1D
Mercury Free:
Yes
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V AC for power circuit conforming to IEC 60947
Minimum Switching Current:
5 mA for Signaling circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Mechanical Durability:
6 Mcycles
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Fire Resistance:
850°C IEC 60695-2-1
Maximum Operating Rate:
3600 cyc/h 60°C
Environmental Disclosure:
ENVPEP1503009EN
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC-1 for power circuit || 66 A (at <60°C) at <= 440 V AC-3 for power circuit || 66 A (at <60°C) at <= 440 V AC-3e for power circuit
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
[Ui] Rated Insulation Voltage:
Signaling circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-4-1
Electrical Durability:
0.7 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3 <= 440 V || 1 Mcycles 66 A AC-3e <= 440 V
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Net Weight:
0.86 kg
Operating Time:
4...19 ms opening || 12...26 ms closing
Maximum Horse Power Rating:
5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp
Protective Cover:
with
Range:
TeSys || TeSys Deca
Mounting Support:
plate || rail
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
[Icw] Rated Short-Time Withstand Current:
520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Control Circuit Type:
AC 50/60 Hz standard
Height:
122 mm
Pvc Free:
Yes
Eu Rohs Directive:
Compliant
$426.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose