Schneider Electric LC1D80A6KUE IEC contactor, TeSys Deca Green, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 250VAC/VDC coil, open style
Schneider Electric
$532.80
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.21 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Rohs Exemption Information:
- Yes
- Flame Retardance:
- V1 conforming to UL 94
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Environmental Disclosure:
- ENVPEP1607010EN
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Warranty:
- 18 months
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Electrical Durability:
- 1 Mcycles 66 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3e <= 440 V
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Depth:
- 120 mm
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V AC for power circuit conforming to IEC 60947
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947
- Mercury Free:
- Yes
- Inrush Power In Va:
- 18-18 VA 50/60 Hz (at 20°C)
- [Icw] Rated Short-Time Withstand Current:
- 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- Power Dissipation Per Pole:
- 9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Signaling Circuit Frequency:
- 25...400 Hz
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
- Weight:
- 1.002 kg
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Coil Technology:
- built-in bidirectional peak limiting
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Eu Rohs Directive:
- Compliant with Exemptions
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Hold-In Power Consumption In Va:
- 1.8-1.8 VA 50/60 Hz (at 20°C)
- Pollution Degree:
- 3
- Heat Dissipation:
- 1.2-1.2 W at 50/60 Hz
- Overvoltage Category:
- III
- Mechanical Durability:
- 6 Mcycles
- Circularity Profile:
- ENVEOLI1607010EN
- Connections - Terminals:
- power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
- Operating Time:
- 55...65 ms closing || 20...80 ms opening
- [Ith] Conventional Free Air Thermal Current:
- 80 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- Range:
- TeSys || TeSys Deca
- Country of Origin:
- France
- Inrush Power In W:
- 14-14 W 20°C)
- Hold-In Power Consumption In W:
- 1.2-1.2 W 20°C
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Mounting Support:
- plate || rail
- [Uc] Control Circuit Voltage:
- 100...250 V AC 50/60 Hz || 100...250 V DC
- Sustainable Offer Status:
- Green Premium product
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Product Or Component Type:
- contactor