Schneider Electric

Schneider Electric LC1D80A6M7 IEC contactor, TeSys Deca, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80A6M7
MPN:
LC1D80A6M7
Condition:
New
Contactor Application:
resistive load || motor control
Weight:
0.86 kg
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Eu Rohs Directive:
Compliant
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Minimum Switching Current:
5 mA for Signaling circuit
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Motor Power Kw:
18.5 kW at 220...230 V AC 50 Hz (AC-3) || 37 kW at 380...400 V AC 50 Hz (AC-3) || 37 kW at 415 V AC 50 Hz (AC-3) || 37 kW at 440 V AC 50 Hz (AC-3) || 37 kW at 500 V AC 50 Hz (AC-3) || 37 kW at 660...690 V AC 50 Hz (AC-3)
Mechanical Durability:
6 Mcycles
Power Dissipation Per Pole:
9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
Range Of Product:
TeSys Deca
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Icw] Rated Short-Time Withstand Current:
520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Protective Treatment:
THIEC 60068-2-30
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
[Uc] Control Circuit Voltage:
220 V AC 50/60 Hz
Depth:
120 mm
Poles Description:
3P
Electrical Durability:
0.7 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3 <= 440 V || 1 Mcycles 66 A AC-3e <= 440 V
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || control circuit 1.7 N.m screw clamp terminals pozidriv No
Compatibility Code:
LC1D
[Ue] Rated Operational Voltage:
power circuit 690 V AC 25...400 Hz || power circuit 300 V DC
Height:
122 mm
Utilisation Category:
AC-1 || AC-4 || AC-3 || AC-3e
Signaling Circuit Frequency:
25...400 Hz
Pollution Degree:
3
Mounting Support:
rail || plate
Range:
TeSys || TeSys Deca
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Operating Time:
4...19 ms opening || 12...26 ms closing
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC-1 for power circuit || 66 A (at <60°C) at <= 440 V AC-3 for power circuit || 66 A (at <60°C) at <= 440 V AC-3e for power circuit
Auxiliary Contact Composition:
1 NO + 1 NC
Coil Technology:
without built-in suppressor module
Flame Retardance:
V1 conforming to UL 94
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
[Ui] Rated Insulation Voltage:
Signaling circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-4-1
Operating Altitude:
0...9842.52 ft (0...3000 m)
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Device Short Name:
LC1D
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Fire Resistance:
850°C IEC 60695-2-1
Reach Free Of Svhc:
Yes
Width:
55 mm
Mercury Free:
Yes
Pole Contact Composition:
3 NO
Circularity Profile:
ENVEOLI1503009EN
Product Or Component Type:
contactor
$426.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose