Schneider Electric

Schneider Electric LC1D80A6P7 IEC contactor, TeSys Deca, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 230VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80A6P7
MPN:
LC1D80A6P7
Condition:
New
Electrical Durability:
0.7 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3 <= 440 V || 1 Mcycles 66 A AC-3e <= 440 V
Device Short Name:
LC1D
Depth:
120 mm
Contactor Application:
resistive load || motor control
Pollution Degree:
3
Power Dissipation Per Pole:
9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 16.5 mm
Signaling Circuit Frequency:
25...400 Hz
Weight:
0.86 kg
Net Weight:
0.86 kg
Mounting Support:
plate || rail
Reach Free Of Svhc:
Yes
Pvc Free:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC-1 for power circuit || 66 A (at <60°C) at <= 440 V AC-3 for power circuit || 66 A (at <60°C) at <= 440 V AC-3e for power circuit
Circularity Profile:
ENVEOLI1503009EN
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
[Icw] Rated Short-Time Withstand Current:
520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Environmental Disclosure:
ENVPEP1503009EN
Maximum Operating Rate:
3600 cyc/h 60°C
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Poles Description:
3P
Product Or Component Type:
contactor
Mechanical Durability:
6 Mcycles
Sustainable Offer Status:
Green Premium product
Country of Origin:
Indonesia
Auxiliary Contact Composition:
1 NO + 1 NC
Pole Contact Composition:
3 NO
Motor Power Kw:
18.5 kW at 220...230 V AC 50 Hz (AC-3) || 37 kW at 380...400 V AC 50 Hz (AC-3) || 37 kW at 415 V AC 50 Hz (AC-3) || 37 kW at 440 V AC 50 Hz (AC-3) || 37 kW at 500 V AC 50 Hz (AC-3) || 37 kW at 660...690 V AC 50 Hz (AC-3)
Warranty:
18 months
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || control circuit 1.7 N.m screw clamp terminals pozidriv No
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Protective Cover:
with
Minimum Switching Current:
5 mA for Signaling circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V AC for power circuit conforming to IEC 60947
Minimum Switching Voltage:
17 V for Signaling circuit
Width:
55 mm
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Coil Technology:
without built-in suppressor module
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Control Circuit Type:
AC 50/60 Hz standard
[Ue] Rated Operational Voltage:
power circuit 690 V AC 25...400 Hz || power circuit 300 V DC
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
$426.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose