Schneider Electric LC1D80AE7 IEC contactor, TeSys Deca, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 48VAC 50/60Hz coil, open style
Schneider Electric
$426.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Eu Rohs Directive:
- Compliant
- Fire Resistance:
- 850°C IEC 60695-2-1
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Control Circuit Type:
- AC 50/60 Hz standard
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm²
- Coil Technology:
- without built-in suppressor module
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Motor Power Kw:
- 22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 37 kW at 415 V AC 50/60 Hz (AC-3) || 37 kW at 440 V AC 50/60 Hz (AC-3) || 37 kW at 500 V AC 50/60 Hz (AC-3) || 37 kW at 660...690 V AC 50/60 Hz (AC-3) || 22 kW at 2
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Utilisation Category:
- AC-1 || AC-4 || AC-3 || AC-3e
- Country of Origin:
- Indonesia
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Net Weight:
- 0.86 kg
- Signaling Circuit Frequency:
- 25...400 Hz
- Height:
- 122 mm
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Flame Retardance:
- V1 conforming to UL 94
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Mercury Free:
- Yes
- Warranty:
- 18 months
- Pole Contact Composition:
- 3 NO
- Contactor Application:
- resistive load || motor control
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Pollution Degree:
- 3
- Protective Treatment:
- THIEC 60068-2-30
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Electrical Durability:
- 0.7 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3 <= 440 V || 1 Mcycles 66 A AC-3e <= 440 V
- Compatibility Code:
- LC1D
- Environmental Disclosure:
- ENVPEP1503009EN
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Sustainable Offer Status:
- Green Premium product
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Product Or Component Type:
- contactor
- Toxic Heavy Metal Free:
- Yes
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping)
- Rohs Exemption Information:
- Yes
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- [Uc] Control Circuit Voltage:
- 48 V AC 50/60 Hz
- [Icw] Rated Short-Time Withstand Current:
- 640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Rated Breaking Capacity:
- 1000 A at 440 V for power circuit conforming to IEC 60947