Schneider Electric

Schneider Electric LC1D80AKUE IEC contactor, TeSys Deca Green, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 100/250VAC/VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80AKUE
MPN:
LC1D80AKUE
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Signaling Circuit Frequency:
25...400 Hz
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Heat Dissipation:
1.2-1.2 W at 50/60 Hz
Sustainable Offer Status:
Green Premium product
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
Operating Altitude:
0...9842.52 ft (0...3000 m)
Pole Contact Composition:
3 NO
Device Short Name:
LC1D
Contactor Application:
resistive load || motor control
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC-1 for power circuit || 66 A (at <60°C) at <= 440 V AC-3 for power circuit || 66 A (at <60°C) at <= 440 V AC-3e for power circuit
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Utilisation Category:
AC-3 || AC-1 || AC-3e
Width:
55 mm
Country of Origin:
France
Height:
122 mm
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
Operating Time:
55...65 ms closing || 20...80 ms opening
Protective Cover:
with
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Halogen Content Performance:
Halogen free plastic parts & cables product
Minimum Switching Current:
5 mA for Signaling circuit
Eu Rohs Directive:
Compliant with Exemptions
Fire Resistance:
850°C IEC 60695-2-1
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V AC for power circuit conforming to IEC 60947
Auxiliary Contact Composition:
1 NO + 1 NC
Mechanical Durability:
6 Mcycles
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Range:
TeSys || TeSys Deca
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Hold-In Power Consumption In Va:
1.8-1.8 VA 50/60 Hz (at 20°C)
Poles Description:
3P
Mercury Free:
Yes
Product Or Component Type:
contactor
Inrush Power In W:
14-14 W 20°C)
Range Of Product:
TeSys Deca
[Icw] Rated Short-Time Withstand Current:
110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Associated Fuse Rating:
125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Coil Technology:
built-in bidirectional peak limiting
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Minimum Switching Voltage:
17 V for Signaling circuit
Pollution Degree:
3
$444.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose