Schneider Electric

Schneider Electric LC1D80AM7 IEC contactor, TeSys Deca, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80AM7
MPN:
LC1D80AM7
Condition:
New
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Range Of Product:
TeSys Deca
Poles Description:
3P
Pole Contact Composition:
3 NO
Protective Treatment:
THIEC 60068-2-30
Compatibility Code:
LC1D
Operating Altitude:
0...9842.52 ft (0...3000 m)
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V AC for power circuit conforming to IEC 60947
Flame Retardance:
V1 conforming to UL 94
Mechanical Durability:
6 Mcycles
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Overvoltage Category:
III
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Net Weight:
0.86 kg
Toxic Heavy Metal Free:
Yes
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Ip Degree Of Protection:
IP20 front face IEC 60529
Eu Rohs Directive:
Compliant
Signaling Circuit Frequency:
25...400 Hz
Heat Dissipation:
4-5 W at 50/60 Hz
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Warranty:
18 months
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Coil Technology:
without built-in suppressor module
Mercury Free:
Yes
Pollution Degree:
3
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Motor Power Kw:
22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 37 kW at 415 V AC 50/60 Hz (AC-3) || 37 kW at 440 V AC 50/60 Hz (AC-3) || 37 kW at 500 V AC 50/60 Hz (AC-3) || 37 kW at 660...690 V AC 50/60 Hz (AC-3) || 22 kW at 2
Maximum Horse Power Rating:
5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Operating Time:
4...19 ms opening || 12...26 ms closing
Product Or Component Type:
contactor
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Contactor Application:
motor control || resistive load
Utilisation Category:
AC-1 || AC-4 || AC-3 || AC-3e
[Ue] Rated Operational Voltage:
power circuit 690 V AC 25...400 Hz || power circuit 300 V DC
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Range:
TeSys || TeSys Deca
Rohs Exemption Information:
Yes
Weight:
0.86 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Control Circuit Type:
AC 50/60 Hz standard
Mounting Support:
rail || plate
Auxiliary Contact Composition:
1 NO + 1 NC
$426.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose