Schneider Electric LC1D80D7 IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 42VAC 50/60Hz coil, open
Schneider Electric
$363.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 150A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 175A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 42 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Warranty:
- 18 months
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Maximum Horse Power Rating:
- 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 30 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 60 hp at 460/480 V AC 50/60 Hz for 3 phas
- Protective Cover:
- with
- [Ue] Rated Operational Voltage:
- power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
- Product Certifications:
- CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
- Reach Free Of Svhc:
- Yes
- Depth:
- 130 mm
- [Uc] Control Circuit Voltage:
- 42 V AC 50/60 Hz
- Range:
- TeSys
- Pvc Free:
- Yes
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Average Impedance:
- 0.8 mOhm - Ith 125 A 50 Hz for power circuit
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
- Climatic Withstand:
- IACS E10 exposure to damp heat
- Heat Dissipation:
- 6-10 W at 50/60 Hz
- Eu Rohs Directive:
- Compliant
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Toxic Heavy Metal Free:
- Yes
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Control Circuit Voltage Limits:
- 0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Pollution Degree:
- 3
- Height:
- 127 mm
- Device Short Name:
- LC1D
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Coil Technology:
- without built-in suppressor module
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Mounting Support:
- plate || rail
- Standards:
- EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
- Signaling Circuit Frequency:
- 25...400 Hz
- Rated Breaking Capacity:
- 1100 A at 440 V for power circuit conforming to IEC 60947
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- Utilisation Category:
- AC-3 || AC-3e || AC-4 || AC-1
- Control Circuit Type:
- AC 50/60 Hz
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
- Rohs Exemption Information:
- Yes
- Width:
- 85 mm
- Motor Power Kw:
- 22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 k
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Contactor Application:
- motor control || resistive load
- Sustainable Packaging:
- Yes
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- [Icw] Rated Short-Time Withstand Current:
- 640 A 40°C - 10 s for power circuit || 990 A 40°C - 1 s for power circuit || 135 A 40°C - 10 min for power circuit || 320 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- Pole Contact Composition:
- 3 NO
- Circularity Profile:
- N/A