Schneider Electric

Schneider Electric LC1D80FE7 IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 115VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D80FE7
MPN:
LC1D80FE7
Condition:
New
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Toxic Heavy Metal Free:
Yes
[Uc] Control Circuit Voltage:
115 V AC 50/60 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Poles Description:
3P
Protective Cover:
with
Control Circuit Voltage Limits:
0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
Motor Power Kw:
22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 k
Weight:
1.59 kg
Mounting Support:
rail || plate
Compatibility Code:
LC1D
Product Or Component Type:
contactor
Sustainable Offer Status:
Green Premium product
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Mechanical Durability:
4 Mcycles
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Minimum Switching Current:
5 mA for Signaling circuit
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - ca
Contactor Application:
resistive load || motor control
Flame Retardance:
V1 conforming to UL 94
Range:
TeSys
Minimum Switching Voltage:
17 V for Signaling circuit
Protective Treatment:
THIEC 60068-2-30
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Overvoltage Category:
III
Ip Degree Of Protection:
IP20 front face IEC 60529
Auxiliary Contact Composition:
1 NO + 1 NC
Circularity Profile:
N/A
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Depth:
130 mm
Inrush Power In Va:
245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
Hold-In Power Consumption In Va:
26-26 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C)
Sustainable Packaging:
Yes
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 990 A 40°C - 1 s for power circuit || 135 A 40°C - 10 min for power circuit || 320 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Mercury Free:
Yes
Control Circuit Type:
AC 50/60 Hz standard
Operating Time:
20...35 ms closing || 6...20 ms opening
Width:
85 mm
Range Of Product:
TeSys Deca
Maximum Horse Power Rating:
7.5 hp at 120 V AC 50/60 Hz for 1 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 30 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 60 hp at 460/480 V AC 50/60 Hz for 3 phas
Climatic Withstand:
IACS E10 exposure to damp heat
Coil Technology:
without built-in suppressor module
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
$363.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 150A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 175A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 115 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose