Schneider Electric LC1D80K7 IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D80K7
MPN:
LC1D80K7
Condition:
New
Power Dissipation Per Pole:
5.1 W AC-3 || 12.5 W AC-1 || 5.1 W AC-3e
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Fire Resistance:
850°C IEC 60695-2-1
Flame Retardance:
V1 conforming to UL 94
Control Circuit Type:
AC 50/60 Hz
Poles Description:
3P
Mercury Free:
Yes
Weight:
1.59 kg
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
Contactor Application:
motor control || resistive load
Net Weight:
1.59 kg
Motor Power Kw:
22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 k
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Product Or Component Type:
contactor
Environmental Disclosure:
ENVPEP110205EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Depth:
130 mm
Operating Time:
20...35 ms closing || 6...20 ms opening
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - ca
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Pvc Free:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
Climatic Withstand:
IACS E10 exposure to damp heat
Minimum Switching Voltage:
17 V for Signaling circuit
Eu Rohs Directive:
Compliant
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Range:
TeSys
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Height:
127 mm
Heat Dissipation:
6-10 W at 50/60 Hz
Mechanical Durability:
4 Mcycles
Sustainable Offer Status:
Green Premium product
Pole Contact Composition:
3 NO
Control Circuit Voltage Limits:
0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
Width:
85 mm
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 990 A 40°C - 1 s for power circuit || 135 A 40°C - 10 min for power circuit || 320 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
[Ie] Rated Operational Current:
125 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Protective Cover:
with
Overvoltage Category:
III
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Coil Technology:
without built-in suppressor module
Utilisation Category:
AC-3 || AC-3e || AC-4 || AC-1
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
Circularity Profile:
N/A
Sustainable Packaging:
Yes
Country of Origin:
Czechia
Compatibility Code:
LC1D
$363.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 150A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 175A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 100 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.