Schneider Electric LC1D95B7 IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VAC 50/60Hz coil, open style
Schneider Electric
$437.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Sustainable Offer Status:
- Green Premium product
- Protective Treatment:
- THIEC 60068-2-30
- Range Of Product:
- TeSys Deca
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Fire Resistance:
- 850°C IEC 60695-2-1
- Pvc Free:
- Yes
- Pollution Degree:
- 3
- Device Short Name:
- LC1D
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- Standards:
- EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
- Product Or Component Type:
- contactor
- Protective Cover:
- with
- Flame Retardance:
- V1 conforming to UL 94
- Eu Rohs Directive:
- Compliant
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Country of Origin:
- Czechia
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - ca
- Motor Power Kw:
- 25 kW at 220...230 V AC 50 Hz (AC-3) || 45 kW at 380...400 V AC 50 Hz (AC-3) || 45 kW at 415...440 V AC 50 Hz (AC-3) || 55 kW at 500 V AC 50 Hz (AC-3) || 45 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 400 V AC 50 Hz (AC-4) || 25 kW at 220...230 V A
- Operating Time:
- 20...35 ms closing || 6...20 ms opening
- Utilisation Category:
- AC-3 || AC-3e || AC-4 || AC-1
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Inrush Power In Va:
- 245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
- Circularity Profile:
- N/A
- Poles Description:
- 3P
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Overvoltage Category:
- III
- Control Circuit Voltage Limits:
- 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
- Width:
- 85 mm
- Product Certifications:
- CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
- Depth:
- 130 mm
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
- Mounting Support:
- plate || rail
- Environmental Disclosure:
- ENVPEP110205EN
- Control Circuit Type:
- AC 50/60 Hz standard
- Rohs Exemption Information:
- Yes
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Height:
- 127 mm
- Sustainable Packaging:
- Yes
- Minimum Switching Current:
- 5 mA for Signaling circuit
- [Icw] Rated Short-Time Withstand Current:
- 1100 A 40°C - 1 s for power circuit || 800 A 40°C - 10 s for power circuit || 400 A 40°C - 1 min for power circuit || 135 A 40°C - 10 min for power circuit || 140 A - 100 ms for Signaling circuit || 120 A - 500 ms for Signaling circuit || 100 A - 1 s
- Pole Contact Composition:
- 3 NO
- [Ie] Rated Operational Current:
- 95 A (at <60°C) at <= 440 V AC-3 for power circuit || 125 A (at <60°C) at <= 690 V AC-1 for power circuit || 95 A (at <60°C) at <= 440 V AC-3e for power circuit
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Toxic Heavy Metal Free:
- Yes
- Irms Rated Making Capacity:
- 1100 A at 440 V AC for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Maximum Horse Power Rating:
- 7.5 hp at 120 V AC 60 Hz for 1 phase motors || 15 hp at 230/240 V AC 60 Hz for 1 phase motors || 30 hp at 200/208 V AC 60 Hz for 3 phase motors || 30 hp at 230/240 V AC 60 Hz for 3 phase motors || 60 hp at 460/480 V AC 60 Hz for 3 phase motors || 60
- Electrical Durability:
- 1.2 Mcycles 95 A AC-3 || 1.3 Mcycles 125 A AC-1 || 1.2 Mcycles 95 A AC-3e