Schneider Electric

Schneider Electric LC1D95L6 Contactor, TeSys Deca, 3P 95A AC-3, <= 440V, aux 1NO+1NC, 200V AC 60Hz coil, screw clamp terminals

(No reviews yet) Write a Review
SKU:
LC1D95L6
MPN:
LC1D95L6
Condition:
New
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Rohs Exemption Information:
Yes
[Uc] Control Circuit Voltage:
200 V AC 60 Hz
Net Weight:
1.61 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 160 A gG at <= 690 V coordination type 2 for power circuit || 200 A gG at <= 690 V coordination type 1 for power circuit
Sustainable Offer Status:
Green Premium product
Height:
127 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Motor Power Kw:
25 kW at 220...230 V AC 50 Hz (AC-3) || 45 kW at 380...400 V AC 50 Hz (AC-3) || 45 kW at 415...440 V AC 50 Hz (AC-3) || 55 kW at 500 V AC 50 Hz (AC-3) || 45 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 400 V AC 50 Hz (AC-4) || 25 kW at 220...230 V A
[Ui] Rated Insulation Voltage:
power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Range:
TeSys
Device Short Name:
LC1D
Pole Contact Composition:
3 NO
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Power Dissipation Per Pole:
12.5 W AC-1 || 7.2 W AC-3
Protective Treatment:
TH 3)IEC 60068-2-30
Toxic Heavy Metal Free:
Yes
Heat Dissipation:
6-10 W at 60 Hz for control circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Minimum Switching Voltage:
17 V for Signaling circuit
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Maximum Operating Rate:
3600 cyc/h 60°C
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
Mounting Support:
plate || rail
Circularity Profile:
N/A
Maximum Horse Power Rating:
7.5 hp at 115 V AC 60 Hz for 1 phase motors || 15 hp at 230/240 V AC 60 Hz for 1 phase motors || 25 hp at 200/208 V AC 60 Hz for 3 phase motors || 30 hp at 230/240 V AC 60 Hz for 3 phase motors || 60 hp at 460/480 V AC 60 Hz for 3 phase motors || 60
Sustainable Packaging:
Yes
Protective Cover:
with
[Icw] Rated Short-Time Withstand Current:
1100 A 40°C - 1 s for power circuit || 800 A 40°C - 10 s for power circuit || 400 A 40°C - 1 min for power circuit || 135 A 40°C - 10 min for power circuit || 140 A - 100 ms for Signaling circuit || 120 A - 500 ms for Signaling circuit || 100 A - 1 s
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable en
Tightening Torque:
control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminal Philips No 2 || power circuit 12 N.m screw terminal flat Ø 6 to Ø 8 mm || power circuit 12 N.m screw terminal hex (Allen key) 4 mm || control
Utilisation Category:
AC-3 || AC-3e || AC-4 || AC-1
Safety Reliability Level:
B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 || B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Depth:
130 mm
Electrical Durability:
1.2 Mcycles 95 A AC-3 || 1.3 Mcycles 125 A AC-1
Overvoltage Category:
III
Fire Resistance:
850°C IEC 60695-2-1
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 60 Hz || 0.85...1.1 Uc -40-55°C operational AC 60 Hz || 1...1.1 Uc 55-70°C operational AC 60 Hz
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Operating Altitude:
0...9842.52 ft (0...3000 m)
Climatic Withstand:
IACS E10 exposure to damp heat
Compatibility Code:
LC1D
Operating Time:
20...35 ms closing || 6...20 ms opening
Reach Free Of Svhc:
Yes
Width:
85 mm
$437.00