Schneider Electric

Schneider Electric LC1D95N7 IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 415VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D95N7
MPN:
LC1D95N7
Condition:
New
Weight:
1.61 kg
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - ca
Power Dissipation Per Pole:
12.5 W AC-1 || 7.2 W AC-3 || 7.2 W AC-3e
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Inrush Power In Va:
245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
Signaling Circuit Frequency:
25...400 Hz
Device Short Name:
LC1D
Control Circuit Type:
AC 50/60 Hz
Operating Time:
20...35 ms closing || 6...20 ms opening
Rohs Exemption Information:
Yes
Country of Origin:
Czechia
Coil Technology:
without built-in suppressor module
Mercury Free:
Yes
Control Circuit Voltage Limits:
0.8...1.1 Uc -40-55°C operational AC 50 Hz || 0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Protective Cover:
with
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
[Uc] Control Circuit Voltage:
415 V AC 50/60 Hz
Electrical Durability:
1.2 Mcycles 95 A AC-3 || 1.3 Mcycles 125 A AC-1 || 1.2 Mcycles 95 A AC-3e
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Range Of Product:
TeSys Deca
Safety Reliability Level:
B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 || B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Toxic Heavy Metal Free:
Yes
Minimum Switching Voltage:
17 V for Signaling circuit
Minimum Switching Current:
5 mA for Signaling circuit
Eu Rohs Directive:
Compliant
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Reach Free Of Svhc:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Insulation Resistance:
> 10 MOhm for Signaling circuit
Poles Description:
3P
Utilisation Category:
AC-3 || AC-3e || AC-4 || AC-1
Flame Retardance:
V1 conforming to UL 94
Product Or Component Type:
contactor
Mounting Support:
rail || plate
Motor Power Kw:
25 kW at 220...230 V AC 50 Hz (AC-3) || 45 kW at 380...400 V AC 50 Hz (AC-3) || 45 kW at 415...440 V AC 50 Hz (AC-3) || 55 kW at 500 V AC 50 Hz (AC-3) || 45 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 400 V AC 50 Hz (AC-4) || 25 kW at 220...230 V A
Pollution Degree:
3
Contactor Application:
resistive load || motor control
Operating Altitude:
0...9842.52 ft (0...3000 m)
Sustainable Offer Status:
Green Premium product
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Pvc Free:
Yes
[Ie] Rated Operational Current:
95 A (at <60°C) at <= 440 V AC-3 for power circuit || 125 A (at <60°C) at <= 690 V AC-1 for power circuit || 95 A (at <60°C) at <= 440 V AC-3e for power circuit
[Icw] Rated Short-Time Withstand Current:
1100 A 40°C - 1 s for power circuit || 800 A 40°C - 10 s for power circuit || 400 A 40°C - 1 min for power circuit || 135 A 40°C - 10 min for power circuit || 140 A - 100 ms for Signaling circuit || 120 A - 500 ms for Signaling circuit || 100 A - 1 s
Circularity Profile:
N/A
Width:
85 mm
$437.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 415 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose