Schneider Electric LC1DT206BD IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 24VDC coil, open style
Schneider Electric
$133.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Tightening Torque:
- control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Utilisation Category:
- AC-1
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Fire Resistance:
- 850°C IEC 60695-2-1
- Device Short Name:
- LC1D
- Mechanical Durability:
- 30 Mcycles
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Coil Technology:
- built-in bidirectional peak limiting diode suppressor
- Eu Rohs Directive:
- Compliant with Exemptions
- Pole Contact Composition:
- 4 NO
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- [Ie] Rated Operational Current:
- 20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Net Weight:
- 0.365 kg
- Pollution Degree:
- 3
- Country of Origin:
- France
- Protective Treatment:
- THIEC 60068-2-30
- Average Impedance:
- 2.5 mOhm - Ith 20 A 50 Hz for power circuit
- Connections - Terminals:
- control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 8 mm
- Pvc Free:
- Yes
- Weight:
- 0.365 kg
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Protective Cover:
- with
- Sustainable Offer Status:
- Green Premium product
- Contactor Application:
- resistive load
- Depth:
- 99 mm
- Circularity Profile:
- ENVEOLI1102030EN
- Control Circuit Type:
- DC standard
- Flame Retardance:
- V1 conforming to UL 94
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Icw] Rated Short-Time Withstand Current:
- 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Power Dissipation Per Pole:
- 1.56 W AC-1
- Overvoltage Category:
- III
- Product Or Component Type:
- contactor
- Time Constant:
- 28 ms
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
- Width:
- 45 mm
- Signaling Circuit Frequency:
- 25...400 Hz
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 20 A (at 60°C) for power circuit
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Poles Description:
- 4P