Schneider Electric LC1DT20BD IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 24VDC coil, open style
Schneider Electric
$133.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Protective Cover:
- with
- Pollution Degree:
- 3
- Utilisation Category:
- AC-1
- [Uc] Control Circuit Voltage:
- 24 V DC
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Overvoltage Category:
- III
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Depth:
- 99 mm
- Warranty:
- 18 months
- Control Circuit Type:
- DC standard
- Weight:
- 0.365 kg
- Time Constant:
- 28 ms
- [Ie] Rated Operational Current:
- 20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Range Of Product:
- TeSys Deca
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Rohs Exemption Information:
- Yes
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Inrush Power In W:
- 5.4-5.4 W 20°C)
- Fire Resistance:
- 850°C IEC 60695-2-1
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Net Weight:
- 0.365 kg
- Signaling Circuit Frequency:
- 25...400 Hz
- Operating Time:
- 20±20 % ms opening || 63±15 % ms closing
- Poles Description:
- 4P
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Product Or Component Type:
- contactor
- Device Short Name:
- LC1D
- Mounting Support:
- plate || rail
- Mechanical Durability:
- 30 Mcycles
- Height:
- 85 mm
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Circularity Profile:
- ENVEOLI1102030EN
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Sustainable Offer Status:
- Green Premium product
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Range:
- TeSys || TeSys Deca
- Country of Origin:
- Indonesia
- [Icw] Rated Short-Time Withstand Current:
- 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Compatibility Code:
- LC1D