Schneider Electric

Schneider Electric LC1DT20FD IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 110VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT20FD
MPN:
LC1DT20FD
Condition:
New
Flame Retardance:
V1 conforming to UL 94
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
TeSys Deca
Minimum Switching Current:
5 mA for Signaling circuit
Inrush Power In W:
5.4-5.4 W 20°C)
Environmental Disclosure:
ENVPEP110230EN
Time Constant:
28 ms
Eu Rohs Directive:
Compliant with Exemptions
Operating Altitude:
0...9842.52 ft (0...3000 m)
Sustainable Offer Status:
Green Premium product
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Hold-In Power Consumption In W:
5.4-5.4 W 20°C
Depth:
99 mm
Ip Degree Of Protection:
IP20 front face IEC 60529
Warranty:
18 months
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
Mercury Free:
Yes
Utilisation Category:
AC-1
Mounting Support:
rail || plate
Mechanical Durability:
30 Mcycles
Range:
TeSys || TeSys Deca
Signaling Circuit Frequency:
25...400 Hz
Protective Treatment:
THIEC 60068-2-30
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Width:
45 mm
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Device Short Name:
LC1D
Weight:
0.365 kg
Auxiliary Contact Composition:
1 NO + 1 NC
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Average Impedance:
2.5 mOhm - Ith 20 A 50 Hz for power circuit
Rohs Exemption Information:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Pole Contact Composition:
4 NO
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Power Dissipation Per Pole:
1.56 W AC-1
Control Circuit Type:
DC standard
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 20 A (at 60°C) for power circuit
Coil Technology:
built-in bidirectional peak limiting diode suppressor
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
Minimum Switching Voltage:
17 V for Signaling circuit
$133.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 110 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose