Schneider Electric LC1DT20G7 IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style
Schneider Electric
$126.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Pollution Degree:
- 3
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Flame Retardance:
- V1 conforming to UL 94
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Eu Rohs Directive:
- Compliant
- Warranty:
- 18 months
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Overvoltage Category:
- III
- Average Impedance:
- 2.5 mOhm - Ith 20 A 50 Hz for power circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Pole Contact Composition:
- 4 NO
- Range Of Product:
- TeSys Deca
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Country of Origin:
- France
- Poles Description:
- 4P
- Coil Technology:
- without built-in suppressor module
- Circularity Profile:
- ENVEOLI1501004
- Net Weight:
- 0.365 kg
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Weight:
- 0.365 kg
- Environmental Disclosure:
- ENVPEP1501004
- Protective Cover:
- with
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
- Fire Resistance:
- 850°C IEC 60695-2-1
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
- Compatibility Code:
- LC1D
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Ie] Rated Operational Current:
- 20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Signaling Circuit Frequency:
- 25...400 Hz
- Mercury Free:
- Yes
- Operating Time:
- 4...19 ms opening || 12...22 ms closing
- Range:
- TeSys || TeSys Deca
- Device Short Name:
- LC1D
- Utilisation Category:
- AC-1
- Depth:
- 92 mm
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Insulation Resistance:
- > 10 MOhm for Signaling circuit