Schneider Electric LC1DT20M7 IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 220VAC 50/60Hz coil, open style
Schneider Electric
$126.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Contactor Application:
- resistive load
- Protective Cover:
- with
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Flame Retardance:
- V1 conforming to UL 94
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Mounting Support:
- rail || plate
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
- Eu Rohs Directive:
- Compliant
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pole Contact Composition:
- 4 NO
- Width:
- 45 mm
- Signaling Circuit Frequency:
- 25...400 Hz
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Pollution Degree:
- 3
- Product Certifications:
- DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Compatibility Code:
- LC1D
- Average Impedance:
- 2.5 mOhm - Ith 20 A 50 Hz for power circuit
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Device Short Name:
- LC1D
- [Uc] Control Circuit Voltage:
- 220 V AC 50/60 Hz
- Toxic Heavy Metal Free:
- Yes
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 20 A (at 60°C) for power circuit
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Power Dissipation Per Pole:
- 1.56 W AC-1
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Poles Description:
- 4P
- Warranty:
- 18 months
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Country of Origin:
- France
- Coil Technology:
- without built-in suppressor module
- Fire Resistance:
- 850°C IEC 60695-2-1
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Product Or Component Type:
- contactor
- Range:
- TeSys || TeSys Deca
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
- Net Weight:
- 0.365 kg
- Range Of Product:
- TeSys Deca
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Rohs Exemption Information:
- Yes