Schneider Electric

Schneider Electric LC1DT25BD IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 4 NO, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT25BD
MPN:
LC1DT25BD
Condition:
New
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Poles Description:
4P
Inrush Power In W:
5.4-5.4 W 20°C)
Insulation Resistance:
> 10 MOhm for Signaling circuit
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Circularity Profile:
ENVEOLI1102030EN
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Environmental Disclosure:
ENVPEP110230EN
Sustainable Offer Status:
Green Premium product
Ip Degree Of Protection:
IP20 front face IEC 60529
Fire Resistance:
850°C IEC 60695-2-1
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Country of Origin:
Singapore
Eu Rohs Directive:
Compliant with Exemptions
[Uc] Control Circuit Voltage:
24 V DC
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Protective Cover:
with
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Mounting Support:
rail || plate
Control Circuit Type:
DC standard
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Minimum Switching Voltage:
17 V for Signaling circuit
Compatibility Code:
LC1D
Range Of Product:
TeSys Deca
Net Weight:
0.365 kg
[Icw] Rated Short-Time Withstand Current:
30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Weight:
0.365 kg
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
Pvc Free:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Maximum Operating Rate:
3600 cyc/h 60°C
Signaling Circuit Frequency:
25...400 Hz
Warranty:
18 months
Protective Treatment:
THIEC 60068-2-30
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Product Or Component Type:
contactor
Time Constant:
28 ms
Auxiliary Contact Composition:
1 NO + 1 NC
Range:
TeSys || TeSys Deca
Power Dissipation Per Pole:
1.56 W AC-1
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pole Contact Composition:
4 NO
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
$166.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose