Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Electrical Durability:
0.8 Mcycles 25 A AC-1 <= 440 V
Mechanical Durability:
30 Mcycles
Compatibility Code:
LC1D
Environmental Disclosure:
ENVPEP110230EN
Contactor Application:
resistive load
Fire Resistance:
850°C IEC 60695-2-1
Poles Description:
4P
Signaling Circuit Frequency:
25...400 Hz
Pvc Free:
Yes
Maximum Operating Rate:
3600 cyc/h 60°C
Operating Altitude:
0...9842.52 ft (0...3000 m)
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Width:
45 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Rohs Exemption Information:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Overvoltage Category:
III
Height:
85 mm
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Country of Origin:
France
Circularity Profile:
ENVEOLI1102030EN
[Uc] Control Circuit Voltage:
12 V DC
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Product Or Component Type:
contactor
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Time Constant:
28 ms
Control Circuit Type:
DC standard
[Icw] Rated Short-Time Withstand Current:
30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Pollution Degree:
3
Insulation Resistance:
> 10 MOhm for Signaling circuit
Hold-In Power Consumption In W:
5.4-5.4 W 20°C
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Inrush Power In W:
5.4-5.4 W 20°C)
Depth:
99 mm
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Operating Time:
20±20 % ms opening || 63±15 % ms closing
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Range:
TeSys || TeSys Deca
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
$166.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 12 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.