TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Pollution Degree:
- 3
- Depth:
- 92 mm
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Weight:
- 0.365 kg
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Operating Time:
- 4...19 ms opening || 12...22 ms closing
- Width:
- 45 mm
- Eu Rohs Directive:
- Compliant
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Sustainable Offer Status:
- Green Premium product
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
- Product Or Component Type:
- contactor
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Pole Contact Composition:
- 4 NO
- Poles Description:
- 4P
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Device Short Name:
- LC1D
- Warranty:
- 18 months
- Coil Technology:
- without built-in suppressor module
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
- Overvoltage Category:
- III
- Contactor Application:
- resistive load
- Height:
- 85 mm
- Mounting Support:
- plate || rail
- Signaling Circuit Frequency:
- 25...400 Hz
- Protective Cover:
- with
- Mercury Free:
- Yes
- Range Of Product:
- TeSys Deca
- Country of Origin:
- Indonesia
- Rohs Exemption Information:
- Yes
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Circularity Profile:
- ENVEOLI1501004
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Electrical Durability:
- 0.8 Mcycles 25 A AC-1 <= 440 V
- [Ie] Rated Operational Current:
- 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Protective Treatment:
- THIEC 60068-2-30
- [Icw] Rated Short-Time Withstand Current:
- 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Pvc Free:
- Yes
- Range:
- TeSys || TeSys Deca
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1