Schneider Electric

Schneider Electric LC1DT32E7 IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 4 NO, 48VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT32E7
MPN:
LC1DT32E7
Condition:
New
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Minimum Switching Voltage:
17 V for Signaling circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Control Circuit Type:
AC 50/60 Hz
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Minimum Switching Current:
5 mA for Signaling circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Compatibility Code:
LC1D
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Icw] Rated Short-Time Withstand Current:
40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Protective Cover:
with
Mounting Support:
plate || rail
Operating Altitude:
0...9842.52 ft (0...3000 m)
Contactor Application:
resistive load
Overvoltage Category:
III
Device Short Name:
LC1D
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
Toxic Heavy Metal Free:
Yes
Height:
91 mm
Warranty:
18 months
Circularity Profile:
ENVEOLI1501004
Environmental Disclosure:
ENVPEP1501004
Mercury Free:
Yes
Range Of Product:
TeSys Deca
Eu Rohs Directive:
Compliant
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Rohs Exemption Information:
Yes
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Heat Dissipation:
2-3 W at 50/60 Hz
Pollution Degree:
3
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamp terminals flat Ø 6 mm || pow
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range:
TeSys || TeSys Deca
Product Or Component Type:
contactor
Coil Technology:
without built-in suppressor module
[Ie] Rated Operational Current:
32 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Rated Breaking Capacity:
300 A at 440 V for power circuit conforming to IEC 60947
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Depth:
99 mm
$189.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 32A resistive load rating. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.