Schneider Electric

Schneider Electric LC1DT32G7 IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT32G7
MPN:
LC1DT32G7
Condition:
New
Toxic Heavy Metal Free:
Yes
Device Short Name:
LC1D
Product Or Component Type:
contactor
Electrical Durability:
1 Mcycles 32 A AC-1 <= 440 V
Power Dissipation Per Pole:
2.5 W AC-1
Protective Cover:
with
Ip Degree Of Protection:
IP20 front face IEC 60529
Protective Treatment:
THIEC 60068-2-30
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Overvoltage Category:
III
Pole Contact Composition:
4 NO
Warranty:
18 months
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
[Icw] Rated Short-Time Withstand Current:
40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Flame Retardance:
V1 conforming to UL 94
Fire Resistance:
850°C IEC 60695-2-1
Coil Technology:
without built-in suppressor module
Product Certifications:
CSA || CCC || GOST || GL || BV || UL || RINA || LROS (Lloyds register of shipping) || DNV
Pollution Degree:
3
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Mercury Free:
Yes
Height:
91 mm
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Weight:
0.425 kg
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Net Weight:
0.425 kg
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Operating Time:
4...19 ms opening || 12...22 ms closing
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Rohs Exemption Information:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Range Of Product:
TeSys Deca
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pvc Free:
Yes
Eu Rohs Directive:
Compliant
[Ie] Rated Operational Current:
32 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Circularity Profile:
ENVEOLI1501004
Range:
TeSys || TeSys Deca
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Heat Dissipation:
2-3 W at 50/60 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Rated Breaking Capacity:
300 A at 440 V for power circuit conforming to IEC 60947
Sustainable Offer Status:
Green Premium product
Control Circuit Type:
AC 50/60 Hz
$189.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 32A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose