TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 32A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Toxic Heavy Metal Free:
- Yes
- Device Short Name:
- LC1D
- Product Or Component Type:
- contactor
- Electrical Durability:
- 1 Mcycles 32 A AC-1 <= 440 V
- Power Dissipation Per Pole:
- 2.5 W AC-1
- Protective Cover:
- with
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Protective Treatment:
- THIEC 60068-2-30
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Overvoltage Category:
- III
- Pole Contact Composition:
- 4 NO
- Warranty:
- 18 months
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- [Icw] Rated Short-Time Withstand Current:
- 40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Flame Retardance:
- V1 conforming to UL 94
- Fire Resistance:
- 850°C IEC 60695-2-1
- Coil Technology:
- without built-in suppressor module
- Product Certifications:
- CSA || CCC || GOST || GL || BV || UL || RINA || LROS (Lloyds register of shipping) || DNV
- Pollution Degree:
- 3
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Mercury Free:
- Yes
- Height:
- 91 mm
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Weight:
- 0.425 kg
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Net Weight:
- 0.425 kg
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Operating Time:
- 4...19 ms opening || 12...22 ms closing
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Rohs Exemption Information:
- Yes
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Range Of Product:
- TeSys Deca
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Pvc Free:
- Yes
- Eu Rohs Directive:
- Compliant
- [Ie] Rated Operational Current:
- 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Circularity Profile:
- ENVEOLI1501004
- Range:
- TeSys || TeSys Deca
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Rated Breaking Capacity:
- 300 A at 440 V for power circuit conforming to IEC 60947
- Sustainable Offer Status:
- Green Premium product
- Control Circuit Type:
- AC 50/60 Hz