Schneider Electric

Schneider Electric LC1DT406BL IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 4 NO, low consumption 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT406BL
MPN:
LC1DT406BL
Condition:
New
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
[Icw] Rated Short-Time Withstand Current:
50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Poles Description:
4P
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Signaling Circuit Frequency:
25...400 Hz
Operating Time:
77±15 % ms closing || 25±20 % ms opening
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Control Circuit Type:
DC low consumption
Sustainable Offer Status:
Green Premium product
Mechanical Durability:
30 Mcycles
Range:
TeSys || TeSys Deca
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Overvoltage Category:
III
Power Dissipation Per Pole:
3.2 W AC-1
Maximum Operating Rate:
3600 cyc/h 60°C
[Uc] Control Circuit Voltage:
24 V DC
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Auxiliary Contact Composition:
1 NO + 1 NC
Minimum Switching Voltage:
17 V for Signaling circuit
Product Certifications:
GL || RINA || BV || UL || CSA || CCC || LROS (Lloyds register of shipping) || DNV || GOST
Warranty:
18 months
Flame Retardance:
V1 conforming to UL 94
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Pollution Degree:
3
Eu Rohs Directive:
Compliant with Exemptions
Circularity Profile:
ENVEOLI110229EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rohs Exemption Information:
Yes
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Protective Cover:
with
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5 || power circuit 1.8 N.m lugs-ring terminals flat Ø 6 mm
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Product Or Component Type:
contactor
Operating Altitude:
0...9842.52 ft (0...3000 m)
Environmental Disclosure:
ENVPEP110229EN
Inrush Power In W:
2.4-2.4 W 20°C)
$294.84

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 4.21 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose