TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 42 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Protective Cover:
- with
- Poles Description:
- 4P
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Power Dissipation Per Pole:
- 3.2 W AC-1
- Pvc Free:
- Yes
- Overvoltage Category:
- III
- [Icw] Rated Short-Time Withstand Current:
- 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Fire Resistance:
- 850°C IEC 60695-2-1
- Range:
- TeSys || TeSys Deca
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Pole Contact Composition:
- 4 NO
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- [Uc] Control Circuit Voltage:
- 42 V AC 50/60 Hz
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Average Impedance:
- 2 mOhm - Ith 40 A 50 Hz for power circuit
- Signaling Circuit Frequency:
- 25...400 Hz
- Compatibility Code:
- LC1D
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Coil Technology:
- without built-in suppressor module
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- [Ie] Rated Operational Current:
- 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Net Weight:
- 0.425 kg
- Rohs Exemption Information:
- Yes
- Width:
- 45 mm
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
- Electrical Durability:
- 1.4 Mcycles 40 A AC-1 <= 440 V
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Weight:
- 0.425 kg
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Pollution Degree:
- 3
- Eu Rohs Directive:
- Compliant
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4
- Warranty:
- 18 months
- Mechanical Durability:
- 15 Mcycles
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Rated Breaking Capacity:
- 450 A at 440 V for power circuit conforming to IEC 60947
- Environmental Disclosure:
- ENVPEP110229EN
- Device Short Name:
- LC1D
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Circularity Profile: