Schneider Electric LC1DT40ED IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 4 NO, 48VDC coil, open style
Schneider Electric
$245.70
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 48 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 4.21 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Depth:
- 107 mm
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Compatibility Code:
- LC1D
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Range Of Product:
- TeSys Deca
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
- Time Constant:
- 28 ms
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
- Mounting Support:
- rail || plate
- [Ie] Rated Operational Current:
- 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
- Signaling Circuit Frequency:
- 25...400 Hz
- Coil Technology:
- built-in bidirectional peak limiting diode suppressor
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamps terminals flat Ø 6 mm || po
- Toxic Heavy Metal Free:
- Yes
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Net Weight:
- 0.425 kg
- Device Short Name:
- LC1D
- Eu Rohs Directive:
- Compliant
- Poles Description:
- 4P
- Contactor Application:
- resistive load
- Protective Cover:
- with
- Warranty:
- 18 months
- Weight:
- 0.425 kg
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Product Certifications:
- DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
- Pole Contact Composition:
- 4 NO
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Flame Retardance:
- V1 conforming to UL 94
- Fire Resistance:
- 850°C IEC 60695-2-1
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Pvc Free:
- Yes
- Protective Treatment:
- THIEC 60068-2-30
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Average Impedance:
- 2 mOhm - Ith 40 A 50 Hz for power circuit
- Sustainable Offer Status:
- Green Premium product
- Overvoltage Category:
- III
- Country of Origin:
- United States
- [Icw] Rated Short-Time Withstand Current:
- 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Range:
- TeSys || TeSys Deca