Schneider Electric

Schneider Electric LC1DT40ED IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 4 NO, 48VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT40ED
MPN:
LC1DT40ED
Condition:
New
Depth:
107 mm
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Compatibility Code:
LC1D
Operating Altitude:
0...9842.52 ft (0...3000 m)
Insulation Resistance:
> 10 MOhm for Signaling circuit
Range Of Product:
TeSys Deca
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Time Constant:
28 ms
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Mounting Support:
rail || plate
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Signaling Circuit Frequency:
25...400 Hz
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamps terminals flat Ø 6 mm || po
Toxic Heavy Metal Free:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Net Weight:
0.425 kg
Device Short Name:
LC1D
Eu Rohs Directive:
Compliant
Poles Description:
4P
Contactor Application:
resistive load
Protective Cover:
with
Warranty:
18 months
Weight:
0.425 kg
Maximum Operating Rate:
3600 cyc/h 60°C
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Pole Contact Composition:
4 NO
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Flame Retardance:
V1 conforming to UL 94
Fire Resistance:
850°C IEC 60695-2-1
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Minimum Switching Voltage:
17 V for Signaling circuit
Pvc Free:
Yes
Protective Treatment:
THIEC 60068-2-30
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Sustainable Offer Status:
Green Premium product
Overvoltage Category:
III
Country of Origin:
United States
[Icw] Rated Short-Time Withstand Current:
50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Range:
TeSys || TeSys Deca
$245.70

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 48 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 4.21 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose