Schneider Electric

Schneider Electric LC1DT40U7 IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 4 NO, 240VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT40U7
MPN:
LC1DT40U7
Condition:
New
Compatibility Code:
LC1D
Pvc Free:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Warranty:
18 months
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Eu Rohs Directive:
Compliant
Weight:
0.425 kg
Pollution Degree:
3
Rohs Exemption Information:
Yes
Net Weight:
0.425 kg
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Coil Technology:
without built-in suppressor module
Operating Altitude:
0...9842.52 ft (0...3000 m)
Pole Contact Composition:
4 NO
Protective Cover:
with
Power Dissipation Per Pole:
3.2 W AC-1
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Fire Resistance:
850°C IEC 60695-2-1
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Mounting Support:
rail || plate
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Contactor Application:
resistive load
[Uc] Control Circuit Voltage:
240 V AC 50/60 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Country of Origin:
Indonesia
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Overvoltage Category:
III
Control Circuit Type:
AC 50/60 Hz
[Icw] Rated Short-Time Withstand Current:
50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Auxiliary Contact Composition:
1 NO + 1 NC
Product Or Component Type:
contactor
Poles Description:
4P
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Range Of Product:
TeSys Deca
$235.56

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose