Schneider Electric

Schneider Electric LC1DT60A6EHE IEC contactor, TeSys Deca Green, nonreversing, 60A resistive, 4 pole, 4 NO, 48/130VAC/VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT60A6EHE
MPN:
LC1DT60A6EHE
Condition:
New
Pole Contact Composition:
4 NO
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Mechanical Durability:
6 Mcycles
Connections - Terminals:
power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
Sustainable Offer Status:
Green Premium product
Operating Time:
55...65 ms closing || 20...80 ms opening
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Weight:
1.230 kg
Ip Degree Of Protection:
IP20 front face IEC 60529
Auxiliary Contact Composition:
1 NO + 1 NC
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 |
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ith] Conventional Free Air Thermal Current:
60 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Mounting Support:
plate || rail
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Depth:
120 mm
Range:
TeSys || TeSys Deca
Minimum Switching Voltage:
17 V for Signaling circuit
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Fire Resistance:
850°C IEC 60695-2-1
Device Short Name:
LC1D
Contactor Application:
resistive load
Coil Technology:
built-in bidirectional peak limiting
Eu Rohs Directive:
Compliant with Exemptions
Operating Altitude:
0...9842.52 ft (0...3000 m)
Minimum Switching Current:
5 mA for Signaling circuit
Environmental Disclosure:
ENVPEP1607010EN
Protective Cover:
with
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
[Icw] Rated Short-Time Withstand Current:
72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Compatibility Code:
LC1D
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms Rated Making Capacity:
800 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Product Or Component Type:
contactor
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Hold-In Power Consumption In Va:
1.4-1.4 VA 50/60 Hz (at 20°C)
Signaling Circuit Frequency:
25...400 Hz
Poles Description:
4P
Country of Origin:
France
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Hold-In Power Consumption In W:
0.9-0.9 W 20°C
Inrush Power In Va:
23-23 VA 50/60 Hz (at 20°C)
Circularity Profile:
ENVEOLI1607010EN
Inrush Power In W:
19-19 W 20°C)
Power Dissipation Per Pole:
5.8 W AC-1
$445.20

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose