Schneider Electric

Schneider Electric LC1DT60A6MD IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 4 NO, 220VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT60A6MD
MPN:
LC1DT60A6MD
Condition:
New
Fire Resistance:
850°C IEC 60695-2-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Mechanical Durability:
10 Mcycles
[Uc] Control Circuit Voltage:
220 V DC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Signaling Circuit Frequency:
25...400 Hz
Eu Rohs Directive:
Compliant with Exemptions
Compatibility Code:
LC1D
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Icw] Rated Short-Time Withstand Current:
320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Insulation Resistance:
> 10 MOhm for Signaling circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Flame Retardance:
V1 conforming to UL 94
Time Constant:
34 ms
Protective Cover:
with
Device Short Name:
LC1D
Operating Time:
50±15 % ms closing || 16...24 ms opening
Tightening Torque:
control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm M3.5 || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 M3.5 || power circuit 6 N.m EverLink BTR screw connectors M6 || control circuit 1.7 N.m EverLink BTR screw c
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Weight:
1.165 kg
Depth:
120 mm
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Protective Treatment:
THIEC 60068-2-30
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Pvc Free:
Yes
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Mounting Support:
rail || plate
Pole Contact Composition:
4 NO
Pollution Degree:
3
Mercury Free:
Yes
Electrical Durability:
0.7 Mcycles 60 A AC-1 <= 440 V
Power Dissipation Per Pole:
5.8 W AC-1
Auxiliary Contact Composition:
1 NO + 1 NC
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
California Proposition 65:
WARNING: Cancer - www.P65Warnings.ca.gov
Inrush Power In W:
19-19 W 20°C)
Maximum Operating Rate:
3600 cyc/h 60°C
Utilisation Category:
AC-1
Contactor Application:
resistive load
$371.30

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 220 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.57 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose