[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Product Or Component Type:
contactor
Height:
122 mm
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Electrical Durability:
0.7 Mcycles 60 A AC-1 <= 440 V
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Power Dissipation Per Pole:
5.8 W AC-1
Protective Treatment:
THIEC 60068-2-30
Minimum Switching Voltage:
17 V for Signaling circuit
Net Weight:
1.165 kg
Auxiliary Contact Composition:
1 NO + 1 NC
Inrush Power In W:
19-19 W 20°C)
Depth:
120 mm
Signaling Circuit Frequency:
25...400 Hz
Rohs Exemption Information:
Yes
Mechanical Durability:
10 Mcycles
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Sustainable Offer Status:
Green Premium product
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
[Uc] Control Circuit Voltage:
110 V DC
Protective Cover:
with
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Warranty:
18 months
Range Of Product:
TeSys Deca
Ip Degree Of Protection:
IP20 front face IEC 60529
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Flame Retardance:
V1 conforming to UL 94
Operating Altitude:
0...9842.52 ft (0...3000 m)
Pvc Free:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
Operating Time:
50±15 % ms closing || 16...24 ms opening
Compatibility Code:
LC1D
Utilisation Category:
AC-1
Overvoltage Category:
III
Eu Rohs Directive:
Compliant
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mounting Support:
rail || plate
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
Tightening Torque:
control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BT
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Range:
TeSys || TeSys Deca
Pollution Degree:
3
Contactor Application:
resistive load
Pole Contact Composition:
4 NO
$371.30

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 110 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.57 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.