Average Impedance:
1.6 mOhm - Ith 60 A 50 Hz for power circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
Electrical Durability:
1.4 Mcycles 60 A AC-1 <= 440 V
Poles Description:
4P
Eu Rohs Directive:
Compliant
Control Circuit Type:
AC 50/60 Hz
Operating Time:
4...19 ms opening || 12...26 ms closing
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Minimum Switching Current:
5 mA for Signaling circuit
[Icw] Rated Short-Time Withstand Current:
320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Country of Origin:
France
Product Certifications:
UL || RINA || DNV || LROS (Lloyds register of shipping) || GL || BV || CCC || CSA || GOST
Width:
70 mm
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Power Dissipation Per Pole:
5.8 W AC-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Mechanical Durability:
6 Mcycles
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Net Weight:
1.09 kg
Flame Retardance:
V1 conforming to UL 94
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Environmental Disclosure:
ENVPEP1503009EN
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Ip Degree Of Protection:
IP20 front face IEC 60529
Compatibility Code:
LC1D
Protective Cover:
with
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Protective Treatment:
THIEC 60068-2-30
Utilisation Category:
AC-1
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Pollution Degree:
3
Auxiliary Contact Composition:
1 NO + 1 NC
Coil Technology:
without built-in suppressor module
Rohs Exemption Information:
Yes
Toxic Heavy Metal Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Operating Altitude:
0...9842.52 ft (0...3000 m)
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Maximum Operating Rate:
3600 cyc/h 60°C
Minimum Switching Voltage:
17 V for Signaling circuit
Depth:
120 mm
Height:
122 mm
Circularity Profile:
ENVEOLI1503009EN
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
$353.16

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 100 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.