TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 400 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Environmental Disclosure:
- ENVPEP1503009EN
- Weight:
- 1.09 kg
- Mounting Support:
- plate || rail
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Protective Cover:
- with
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Sustainable Offer Status:
- Green Premium product
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Poles Description:
- 4P
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Toxic Heavy Metal Free:
- Yes
- Pole Contact Composition:
- 4 NO
- Control Circuit Type:
- AC 50/60 Hz
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Electrical Durability:
- 1.4 Mcycles 60 A AC-1 <= 440 V
- Pvc Free:
- Yes
- [Uc] Control Circuit Voltage:
- 400 V AC 50/60 Hz
- Mechanical Durability:
- 6 Mcycles
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- Signaling Circuit Frequency:
- 25...400 Hz
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Device Short Name:
- LC1D
- Power Dissipation Per Pole:
- 5.8 W AC-1
- Coil Technology:
- without built-in suppressor module
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
- Mercury Free:
- Yes
- Country of Origin:
- France
- Width:
- 70 mm
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Product Certifications:
- RINA || GL || DNV || CSA || CCC || BV || UL || LROS (Lloyds register of shipping) || GOST
- Range:
- TeSys || TeSys Deca
- Average Impedance:
- 1.6 mOhm - Ith 60 A 50 Hz for power circuit
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Fire Resistance:
- 850°C IEC 60695-2-1
- Utilisation Category:
- AC-1
- Pollution Degree:
- 3
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Eu Rohs Directive:
- Compliant
- Protective Treatment: