Operating Altitude:
0...9842.52 ft (0...3000 m)
Inrush Power In W:
19-19 W 20°C)
Environmental Disclosure:
ENVPEP1503009EN
Signaling Circuit Frequency:
25...400 Hz
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Electrical Durability:
0.5 Mcycles 80 A AC-1 <= 440 V
Minimum Switching Voltage:
17 V for Signaling circuit
Utilisation Category:
AC-1
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Mercury Free:
Yes
Warranty:
18 months
Insulation Resistance:
> 10 MOhm for Signaling circuit
Product Or Component Type:
contactor
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Reach Free Of Svhc:
Yes
Pollution Degree:
3
Power Dissipation Per Pole:
10.2 W AC-1
Eu Rohs Directive:
Compliant
Overvoltage Category:
III
Poles Description:
4P
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Country of Origin:
France
Width:
70 mm
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Depth:
120 mm
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Average Impedance:
1.6 mOhm - Ith 80 A 50 Hz for power circuit
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Control Circuit Type:
DC standard
Tightening Torque:
power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 2.5-25 mm² hexagonal 4 mm || control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2 || power circuit 2.5 N.
Net Weight:
1.225 kg
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Device Short Name:
LC1D
Time Constant:
34 ms
Flame Retardance:
V1 conforming to UL 94
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Protective Treatment:
THIEC 60068-2-30
Auxiliary Contact Composition:
1 NO + 1 NC
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Weight:
1.225 kg
Circularity Profile:
ENVEOLI1503009EN
Ip Degree Of Protection:
IP20 front face IEC 60529
Minimum Switching Current:
5 mA for Signaling circuit
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
$535.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.70 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.